Carbon Monoxide (CO) Gas Sensor RS-CO-V05-2-2000P-2 0-5V
The RS-CO-V05-2-2000P-2 sensor is a fixed carbon monoxide gas detector that outputs a 0–5 V analog signal corresponding to CO concentration. Its enclosure is designed for stable, continuous mounting in indoor or semi-industrial settings. The sensor is meant for permanent installation in areas where carbon monoxide accumulation must be monitored, such as utility rooms, plant areas, or enclosed spaces.
Gas molecules enter the sensor via a diffusion port or membrane and reach the internal sensing element (typically electrochemical). The interaction of CO with the sensing electrode causes a proportional change in voltage (or current, internally), which is conditioned and converted to a voltage output in the span 0 to 5 V. The internal signal processing typically includes compensation for ambient temperature and humidity variations to improve accuracy and stability.
Over time, the RS-CO-V05-2-2000P-2 maintains stability via low drift electronics and self-diagnostic capability (in some implementations). It interfaces directly with control systems, alarms, or data acquisition units that accept 0–5 V analog inputs. In safety systems, it can trigger alerts or ventilation when CO levels rise above pre-set thresholds. Its construction aims to minimize maintenance and provide reliable performance over long durations.
Features:
- Linear 0–5 V analog output scaled to CO concentration.
- Measurement range designed for CO up to ~2000 ppm.
- Integrated temperature and humidity compensation.
- Low drift over long term usage.
- Fast response to changing CO levels.
- Rugged enclosure suitable for typical industrial / indoor environments.
- Easy to interface with controllers, PLCs, analog acquisition systems.
Specifications:
| Parameter | Value / Range |
|---|---|
| Measuring gas: | Carbon monoxide (CO) |
| Output signal: | 0 – 5 V analog |
| Measuring range: | 0 – 2000 ppm |
| Accuracy: | ± a few % of reading or ± several ppm |
| Response time: | Seconds to tens of seconds |
| Operating temperature: | –20 °C to +50 °C (estimate) |
| Humidity range: | 0 – 95 % RH non-condensing |
| Power supply (input): | ~10 – 30 V DC (or specified supply) |
| Drift: | Low long-term drift |
| Enclosure protection / IP: | Dust / moisture resistant (IP rating) |
| Dimensions / Weight: | As per manufacturer’s mechanical data |
Applications:
- Indoor air safety monitoring.
- Industrial process control safety.
- Garage / parking ventilation control.
- Building HVAC safety systems.
- Fuel appliance safety monitoring.
- Tunnel / underground safety systems.
Package Contents:
- 1x Carbon Monoxide (CO) Gas Sensor RS-CO-V05-2-2000P-2 0-5V




Reviews