Carbon Monoxide (CO) Gas Sensor RS-COWS-N01-2-2000P-5 RS485
The RS-COWS-N01-2-2000P-5 (RS485) is a smart CO gas transmitter combining gas, temperature and humidity sensing in one unit. It comes in a rugged, sealed enclosure to shield internal sensors from dust, moisture, and environmental stress. Its compact and modular design enables installation on walls or panels in industrial or building control contexts, with the ability to network multiple units via the RS-485 bus.
When powered (10–30 V DC), the unit initializes and stabilizes, then begins measuring ambient CO concentration, ambient temperature, and humidity at periodic intervals (every 2 seconds). The measurements are digitized and sent over RS-485 using the Modbus-RTU protocol. This digital communication mitigates the signal degradation and noise susceptibility that often affects analogue transmissions over distance.
In a networked monitoring system, multiple units can share a common RS-485 line, each with a unique address. The central controller (PLC, SCADA, BMS) polls each sensor for its current readings and can trigger actions (ventilation, alarms) based on threshold crossings. The integrated multi-parameter sensing in one package simplifies deployment and wiring, making it suitable for continuous environmental safety monitoring in parking garages, mechanical rooms, laboratories, or HVAC zones.
Features:
- Digital communication via RS-485 / Modbus-RTU.
- Combined sensing of CO, temperature, and humidity.
- Wide power supply input range (10–30 V DC).
- Stable signal transmission over long RS-485 lines.
- Configurable address, baud rate, and device parameters.
- Rapid update interval (2 seconds).
- Protection in sealed housing for robustness.
Specifications:
| Parameter | Value |
|---|---|
| CO measurement range: | 0 – 5000 ppm (configurable) |
| CO accuracy: | ± (40 ppm + 3% of full scale) at 25 °C |
| Temperature range: | –40 °C to +80 °C |
| Temperature accuracy: | ± 0.5 °C |
| Humidity range: | 0 – 100 % RH |
| Humidity accuracy: | ± 3 % RH |
| Power supply voltage: | 10 – 30 V DC |
| Average current: | < 85 mA |
| Data update (refresh) time: | 2 seconds |
| Warm-up time: | 2 minutes, up to 10 minutes for full precision |
| Stability (drift): | < 2 % full scale |
| Nonlinearity: | < 1 % full scale |
| Communication interface: | RS-485, Modbus-RTU |
| Operating pressure: | 90 – 110 kPa |
Applications:
- Indoor air quality monitoring.
- Parking garages and vehicle exhaust zones.
- Mechanical / boiler rooms.
- HVAC control and ventilation systems.
- Industrial safety and emission monitoring.
Package Contents:
- 1x Carbon Monoxide (CO) Gas Sensor RS-COWS-N01-2-2000P-5 RS485