KYORITSU 1009 Digital Multimeter

KYORITSU 1009 is a compact digital multimeter with auto-ranging, reliable measurements, and essential safety features for everyday electrical testing.

2,750.00 EGP

Buy Now
Availability: In Stock
Brand:
KYORITSU 1009 Digital Multimeter

The KYORITSU 1009 Digital Multimeter embodies a marriage of robust safety engineering and intuitive operation within a compact form. Housed in a reinforced casing with dual insulation, it presents a reassuring solidity in the hand while protecting users from accidental contact with live circuits . The clear, auto-ranging LCD display adapts seamlessly to measured values, minimizing manual adjustments and keeping the interface uncluttered. Beneath this simplicity lie thoughtfully arranged controls: a tactile function switch that clicks sharply into place, and dedicated keys for zeroing, range override, and data hold, each positioned for ergonomic thumb access.

Internally, the meter employs advanced signal-processing circuitry that filters out electrical noise, ensuring that readings remain stable even in electrically “dirty” environments. A built-in relative mode lets operators compare live measurements against a stored baseline without navigating menus, and a backlit display automatically illuminates low-light conditions, preserving visibility without added bulk . Despite its sophisticated electronics, the instrument maintains a slender profile, slipping easily into a tool pouch or pocket. Overall, the 1009 model strikes a balance between rugged reliability and user-centric design, offering swift adaptability across a variety of measurement scenarios without overwhelming the user with complexity.

Features:
  • Designed to international safety standards (IEC 61010-1, IEC 61010-2-033 CAT III 300 V, Pollution Degree 2; IEC 61010-031).
  • REL (relative) function to display the difference between live readings and a stored baseline.
  • Auto power-off to conserve battery when idle.
  • Data hold function to freeze the displayed measurement.
  • Diode and continuity check modes with audible buzzer.
  • Auto-ranging across voltage, current, resistance, capacitance, and frequency ranges.
  • Frequency measurement capability (1 Hz–10 MHz).
  • DUTY-cycle measurement (pulse-width/pulse-period as a percentage).
  • Fuse-protected current inputs for enhanced safety.
  • Holster protection against mechanical shock during field use.
Specifications:
Specification Detail
DC Voltage: 0–600 V (5 autoranging ranges); input impedance 10 MΩ
Accuracy:
±0.6 % rdg ± 4 dgt on 400 mV & 4 V
±1.0 % rdg ± 4 dgt on 40 V
±1.6 % rdg ± 4 dgt (50/60 Hz) on 400 V
±2.0 % rdg ± 4 dgt (≤ 400 Hz) on 600 V
AC Voltage: 0–600 V (4 autoranging ranges)
Accuracy:
±1.6 % rdg ± 4 dgt (50/60 Hz)
±2.6 % rdg ± 4 dgt (≤ 400 Hz)
DC Current (µA/mA): 0–400 µA / 0–4000 µA (2 autoranging),
0–40 mA / 0–400 mA (2 autoranging);
Accuracy: up to
±3.5 % rdg ± 10 dgt on µA
±3.0 % rdg ± 5 dgt on mA
DC Current (A): 0–4 A / 0–10 A (2 autoranging)
Allowable measurement time 15 s
Accuracy: ±2.0 % rdg ± 5 dgt on 10 A
AC Current (µA/mA): 0–400 µA / 0–4000 µA (2 autoranging)
0–40 mA / 0–400 mA (2 autoranging)
Accuracy: ±3.0 % rdg ± 5 dgt (50/60 Hz)
AC Current (A): 0–4 A / 0–10 A (2 autoranging)
Allowable measurement time 15 s
Accuracy ±2.6 % rdg ± 5 dgt
Resistance: 0–40 MΩ (6 autoranging ranges)
Test current 0.4 mA
Continuity buzzer below 100 Ω
Accuracy ±1.0 % rdg ± 5 dgt (0–400 Ω) to ±3.5 % rdg ± 5 dgt (4 MΩ–40 MΩ)
Diode Test: Open-circuit voltage 1.5 V
Measuring current 0.4 mA
Accuracy ±3.0 % rdg ± 5 dgt
Capacitance: 100 µF (5 autoranging)
Accuracy ±2.5 % rdg ± 5 dgt
Measurement time up to 15 s on largest range
Frequency: 5.12 Hz–10 MHz (8 autoranging)
Input sensitivity >1.5 V RMS (≤ 1 MHz), >2 V RMS (> 1 MHz)
Accuracy ±0.1 % rdg ± 5 dgt
Duty Cycle: 0.1–99.9 % (pulse width/pulse period)
Accuracy ±2.5 % rdg ± 5 dgt
Display: LCD, max. 3999 counts (5119 for Hz); “OL” overload indication; sampling rate 400 ms
Auto-Ranging: Automatic range shifting above 3999 and below 360 counts; manual override via RANGE key
Safety Standards: IEC 61010-1, IEC 61010-2-033 CAT III 300 V; IEC 61010-031; IEC 61326-1/-2-2 (EMC)
Insulation Resistance: ≥ 10 MΩ at DC 1000 V between circuitry and enclosure
Withstand Voltage: ≥ AC 3470 V for 5 s between circuitry and enclosure
Overload Protection: Voltage: 250 V RMS on 400 mV range, 600 V RMS on others; Resistance/Capacitance/Frequency: 250 V RMS for 10 s
Current: fused at 0.5 A/10 A (600 V)
Operating Conditions: Indoor use, altitude ≤ 2000 m; 0 °C–40 °C, ≤ 80 % RH; storage –20 °C–60 °C, ≤ 70 % RH
Dimensions & Weight: 155 × 75 × 33 mm; approx. 260 g (with batteries)
Power Source: Two R6P (AA) 1.5 V cells
Fuses: M-8918F: 600 V/500 mA; M-8919F: 600 V/10 A (fast-acting, φ 6.3 × 32 mm)
Accessories (if considered spec): Test leads (M-7066A), holster
Applications:
  • Electrical Maintenance & Troubleshooting.
  • Electronics Testing.
  • Educational Labs.
  • DIY Projects.
  • Automotive Work.
  • Field Servicing.
Package Include:
  • 1x Test Lead (M-7066A)
  • 2x R6P (AA) Batteries
  • 1x Holster
  • 1x Instruction Manual