KYORITSU 1009 Digital Multimeter
The KYORITSU 1009 Digital Multimeter embodies a marriage of robust safety engineering and intuitive operation within a compact form. Housed in a reinforced casing with dual insulation, it presents a reassuring solidity in the hand while protecting users from accidental contact with live circuits . The clear, auto-ranging LCD display adapts seamlessly to measured values, minimizing manual adjustments and keeping the interface uncluttered. Beneath this simplicity lie thoughtfully arranged controls: a tactile function switch that clicks sharply into place, and dedicated keys for zeroing, range override, and data hold, each positioned for ergonomic thumb access.
Internally, the meter employs advanced signal-processing circuitry that filters out electrical noise, ensuring that readings remain stable even in electrically “dirty” environments. A built-in relative mode lets operators compare live measurements against a stored baseline without navigating menus, and a backlit display automatically illuminates low-light conditions, preserving visibility without added bulk . Despite its sophisticated electronics, the instrument maintains a slender profile, slipping easily into a tool pouch or pocket. Overall, the 1009 model strikes a balance between rugged reliability and user-centric design, offering swift adaptability across a variety of measurement scenarios without overwhelming the user with complexity.
Features:
- Designed to international safety standards (IEC 61010-1, IEC 61010-2-033 CAT III 300 V, Pollution Degree 2; IEC 61010-031).
- REL (relative) function to display the difference between live readings and a stored baseline.
- Auto power-off to conserve battery when idle.
- Data hold function to freeze the displayed measurement.
- Diode and continuity check modes with audible buzzer.
- Auto-ranging across voltage, current, resistance, capacitance, and frequency ranges.
- Frequency measurement capability (1 Hz–10 MHz).
- DUTY-cycle measurement (pulse-width/pulse-period as a percentage).
- Fuse-protected current inputs for enhanced safety.
- Holster protection against mechanical shock during field use.
Specifications:
| Specification | Detail |
|---|---|
| DC Voltage: | 0–600 V (5 autoranging ranges); input impedance 10 MΩ Accuracy: ±0.6 % rdg ± 4 dgt on 400 mV & 4 V ±1.0 % rdg ± 4 dgt on 40 V ±1.6 % rdg ± 4 dgt (50/60 Hz) on 400 V ±2.0 % rdg ± 4 dgt (≤ 400 Hz) on 600 V |
| AC Voltage: | 0–600 V (4 autoranging ranges) Accuracy: ±1.6 % rdg ± 4 dgt (50/60 Hz) ±2.6 % rdg ± 4 dgt (≤ 400 Hz) |
| DC Current (µA/mA): | 0–400 µA / 0–4000 µA (2 autoranging), 0–40 mA / 0–400 mA (2 autoranging); Accuracy: up to ±3.5 % rdg ± 10 dgt on µA ±3.0 % rdg ± 5 dgt on mA |
| DC Current (A): | 0–4 A / 0–10 A (2 autoranging) Allowable measurement time 15 s Accuracy: ±2.0 % rdg ± 5 dgt on 10 A |
| AC Current (µA/mA): | 0–400 µA / 0–4000 µA (2 autoranging) 0–40 mA / 0–400 mA (2 autoranging) Accuracy: ±3.0 % rdg ± 5 dgt (50/60 Hz) |
| AC Current (A): | 0–4 A / 0–10 A (2 autoranging) Allowable measurement time 15 s Accuracy ±2.6 % rdg ± 5 dgt |
| Resistance: | 0–40 MΩ (6 autoranging ranges) Test current 0.4 mA Continuity buzzer below 100 Ω Accuracy ±1.0 % rdg ± 5 dgt (0–400 Ω) to ±3.5 % rdg ± 5 dgt (4 MΩ–40 MΩ) |
| Diode Test: | Open-circuit voltage 1.5 V Measuring current 0.4 mA Accuracy ±3.0 % rdg ± 5 dgt |
| Capacitance: | 100 µF (5 autoranging) Accuracy ±2.5 % rdg ± 5 dgt Measurement time up to 15 s on largest range |
| Frequency: | 5.12 Hz–10 MHz (8 autoranging) Input sensitivity >1.5 V RMS (≤ 1 MHz), >2 V RMS (> 1 MHz) Accuracy ±0.1 % rdg ± 5 dgt |
| Duty Cycle: | 0.1–99.9 % (pulse width/pulse period) Accuracy ±2.5 % rdg ± 5 dgt |
| Display: | LCD, max. 3999 counts (5119 for Hz); “OL” overload indication; sampling rate 400 ms |
| Auto-Ranging: | Automatic range shifting above 3999 and below 360 counts; manual override via RANGE key |
| Safety Standards: | IEC 61010-1, IEC 61010-2-033 CAT III 300 V; IEC 61010-031; IEC 61326-1/-2-2 (EMC) |
| Insulation Resistance: | ≥ 10 MΩ at DC 1000 V between circuitry and enclosure |
| Withstand Voltage: | ≥ AC 3470 V for 5 s between circuitry and enclosure |
| Overload Protection: | Voltage: 250 V RMS on 400 mV range, 600 V RMS on others; Resistance/Capacitance/Frequency: 250 V RMS for 10 s Current: fused at 0.5 A/10 A (600 V) |
| Operating Conditions: | Indoor use, altitude ≤ 2000 m; 0 °C–40 °C, ≤ 80 % RH; storage –20 °C–60 °C, ≤ 70 % RH |
| Dimensions & Weight: | 155 × 75 × 33 mm; approx. 260 g (with batteries) |
| Power Source: | Two R6P (AA) 1.5 V cells |
| Fuses: | M-8918F: 600 V/500 mA; M-8919F: 600 V/10 A (fast-acting, φ 6.3 × 32 mm) |
| Accessories (if considered spec): | Test leads (M-7066A), holster |
Applications:
- Electrical Maintenance & Troubleshooting.
- Electronics Testing.
- Educational Labs.
- DIY Projects.
- Automotive Work.
- Field Servicing.
Package Include:
- 1x Test Lead (M-7066A)
- 2x R6P (AA) Batteries
- 1x Holster
- 1x Instruction Manual