KYORITSU KEW 3005A Digital Insulation

KYORITSU KEW 3005A is a digital insulation tester for measuring insulation resistance, continuity, and AC voltage with safety and auto discharge features.

15,500.00 EGP

Buy Now
Availability: In Stock
Brand:
KYORITSU KEW 3005A Digital Insulation

The Kyoritsu KEW 3005A is a handheld digital instrument designed primarily for measuring insulation resistance and continuity in electrical circuits. Encased in a durable housing with protective finger guards and fittings for a strap belt, it features a liquid crystal display and a 30-segment bar graph to indicate readings. Powered by eight AA batteries, it delivers test voltages of 250 V, 500 V, or 1000 V DC, enabling users to verify insulation integrity up to 1999 MΩ. In continuity mode, it applies a test current to detect resistance as low as 0.20 Ω, with a measuring range up to 1999 Ω, and can also display AC voltages up to 600 V .

A live circuit warning indicator and buzzer alert the operator if the circuit under test is energized, enhancing safety. After insulation testing, built-in auto discharge circuitry removes residual charge from capacitive components automatically, and an audible confirmation indicates when it is safe to touch the circuit. The instrument’s microprocessor-controlled dual integration system ensures stable, repeatable measurements even under varying temperature and battery conditions.

Lightweight (≈970 g without batteries) and designed to IEC CAT III 300 V standards, the KEW 3005A is suited for field service, maintenance, and troubleshooting of electrical equipment such as motors, transformers, switchgear, and cables.

Features:
  • Designed and tested to comply with safety standards: IEC 61010-1, IEC 61010-2-030 CAT III 300 V, Pollution Degree 2; IEC 61010-031; IEC 61557-1,2,4,10.
  • Bargraph display to visualize measured results.
  • Strap belt attachment for both-hands-free operation.
  • Live circuit warning indication and audible buzzer.
  • Auto discharge function to remove stored charge after insulation tests.
  • Auto power-off after approximately 10 minutes of inactivity.
Specifications:
Specification Details
Insulation Resistance Ranges: • 0 – 19.99 MΩ / 0 – 199.9 MΩ / 0 – 1999 MΩ at 250 V, 500 V, 1000 V DC
• Open-circuit voltage: 250 V DC ±20 % (250 V range), 500 V DC ±20 % (500 V range), 1000 V DC ±20 % (1000 V range)
• Nominal current: ≥1 mA DC at 0.25 MΩ (250 V), 0.5 MΩ (500 V), 1 MΩ (1000 V)
• Short-circuit current: 1.5 mA DC
Insulation Accuracy: • 20 MΩ, 200 MΩ: ±1.5 % reading ±5 digits
• 2000 MΩ (0 – 1 GΩ): ±10 % reading ±3 digits
• 2000 MΩ (1 – 2 GΩ): ±3 % reading ±3 digits
Continuity Ranges: • 20 Ω (0 – 19.99 Ω)
200 Ω (0 – 199.9 Ω)
2000 Ω (0 – 1999 Ω)
• Open-circuit voltage: 7 – 12 V
• Measuring current: ≥200 mA at 0.2 Ω
• Accuracy: ±1.5 % reading ±5 digits (20 Ω)
±1.5 % reading ±3 digits (200 Ω & 2000 Ω)
AC Voltage Indication: 0 – 600 V AC ±5 % reading ±3 digits
Typical Number of Measurements: • Insulation: ≥1000 tests at 0.5 MΩ load (batteries ≥8 V)
• Continuity: ≥700 tests at 1 Ω load
Operating Uncertainty (IEC 61557-2,-4): • 1000 V, 20 MΩ (0.50 – 19.99 MΩ): ±30 %
• 1000 V, 200 MΩ (1 – 199.9 MΩ); 2000 MΩ (10 – 1000 MΩ)
• 500 V, 20 MΩ (0.50 – 19.99 MΩ); 200 MΩ (1 – 199.9 MΩ); 2000 MΩ (10 – 100 MΩ)
• 250 V, 20 MΩ (0.25 – 19.99 MΩ); 200 MΩ (1 – 199.9 MΩ); 2000 MΩ (10 – 100 MΩ)
• Continuity: 20 Ω (0.20 – 19.99 Ω), 200 Ω (1 – 199.9 Ω), 2000 Ω (10 – 1999 Ω)
Standards & Certifications: IEC 61010-1; IEC 61010-2-030 CAT III 300 V, Pollution Degree 2; IEC 61010-031; IEC 61557-1,2,4,10; IEC 61326-2-2 EMC; IEC 60529 (IP54 dust & drip proof); IEC 50581 (RoHS compliant)
Display: • LCD (Max count 1999) with unit indicators
• 30-segment bar graph (20 segments on Ω range)
• “OL” for over-range indication
• “NULL” symbol during auto-null operation
Sample Rate: 0.5 to 2.5 readings per second
Operating Temperature & Humidity: 0 °C to +40 °C; up to 85 % RH
Storage Temperature & Humidity: –20 °C to +60 °C; up to 75 % RH
Altitude (Use Location): ≤2000 m
Insulation & Withstand Voltage: • Insulation: ≥50 MΩ at 1000 V DC (between circuitry and housing)
• Withstand: 3470 V AC for 5 seconds (between circuitry and housing)
Overload Protection: • Insulation: 250 V range → 300 V DC for 10 s
500 V range → 600 V DC for 10 s
1000 V range → 1200 V DC for 10 s
• Continuity (20/200/2000 Ω ranges): 440 V AC for 1 minute (fused protection)
Dimensions (L × W × D): 185 × 167 × 89 mm
Weight: • 3005A: ≈970 g (with batteries)
Power Source: 8 × R6P (AA) 1.5 V batteries (or equivalent)
Auto-Power-Off: Automatically turns off ≈10 minutes after last switch operation Standby current 75 µA
Operating System: Dual integration microprocessor control
Applications:
  • Measuring insulation resistance in electrical installations.
  • Conducting continuity tests on wiring systems.
  • Detecting AC voltage presence in circuits.
  • Ensuring safety and compliance in electrical maintenance.
Package Contents:
  • 1x Test Probe MODEL 7122B
  • 1x Strap belt
  • 1x Test probe pouch
  • 8x Batteries (R6P AA)
  • 1x Instruction manual
  • 1x Spare fuse F600 V/500 mA