UNI-T UTE9802+ Digital Power Meter
The UNI‑T UTE9802+ is an economical, portable digital power meter that combines multiple measurements voltage, current, active power, apparent power, power factor, and frequency into a single handheld instrument. Its VA‑style “broken‑code” display presents numeric data and status icons clearly, while a robust 32‑bit MCU and high‑speed A/D converter ensure fast, accurate readings.
True‑RMS measurement lets the UTE9802+ handle complex waveforms full‑wave, half‑wave, and irregular signals alike making it ideal for both AC and DC testing. It supports AC, DC, and combined AC+DC (T‑RMS) modes over a wide input span (3 V to 700 V; 0.5 mA to 24 A), so you can tackle everything from battery‑powered circuits to high‑voltage mains.
Built‑in auto/manual ranging and a selectable averaging filter stabilize readings on fluctuating loads. Upper/lower‑limit alarms (audible and visual) aid batch testing, while RS‑232/RS‑485 with SCPI/Modbus makes remote data logging and PLC integration straightforward. Rugged silicone‑protected feet guard against bumps and drops, and full‑size stands let you position the meter hands‑free on a workbench or test rack.
Features:
- VA‑style broken‑code LCD display with intuitive status icons.
- Multi‑window simultaneous readout of V, A, W, PF/Hz.
- AC, DC, and AC+DC (T‑RMS) measurement modes (UTE9802+ only).
- True‑RMS readings for accurate tracking of complex waveforms.
- Auto and manual range switching on both voltage and current channels.
- Selectable moving‑average filter (8/16/32/64 samples) to stabilize readings.
- User‑settable upper/lower limit with sound‑and‑light alarm.
- RS‑232 and RS‑485 communications supporting SCPI and Modbus protocols.
- Compact, portable design with silicone corner protection and fold‑out stands.
Specifications:
| Parameter | UTE9802+ |
|---|---|
| Display: | 5 digits “broken‑code” (4 windows) |
| Update Rate: | 0.1 s/0.25 s/0.5 s/1 s/2 s/5 s |
| Measurement Modes: | AC, DC, AC+DC (T‑RMS) |
| Voltage Range: | 3.0 V – 600 V (auto/manual: 75/150/300/600 V) |
| Voltage Accuracy: | DC: ±(0.4% rdg + 0.1% rng + 1 dgt) |
| 40 Hz–66 Hz: ±(0.4% rdg + 0.1% rng + 1 dgt) | |
| 66 Hz–400 Hz: ±(0.3% rdg + 0.2% rng + 1 dgt) | |
| Voltage Resolution: | 0.01 V/0.1 V |
| Current Range: | 0.5 mA – 20 A (auto/manual: 0.5 A/2 A/8 A/20 A) |
| Current Accuracy: | Same formula as voltage; see above |
| Current Resolution: | 0.1 mA/1 mA |
| Power Range: | 1 W – 12 kW |
| Power Accuracy (PF = 1): | Same as voltage range formula |
| Power Resolution: | 0.001 W/0.01 W/0.1 W/1 W |
| Power Factor Range/Acc: | –1.000 – 1.000 / ±(0.004 + 0.001×rdg + 1 dgt) |
| Frequency Range/Acc: | DC, 40 Hz – 400 Hz / ±(0.1% rdg + 1 dgt) |
| Crest Factor: | Voltage/current crest measurement |
| Auto‑range Thresholds: | Increase at 110% of range; decrease at 80% (CF < 2) |
| Peak Measurement: | Up to 700 V, 24 A |
| Hold, Mute, Lock: | √, √, √ |
| Interfaces: | RS‑232 (DB9 TX/RX/GND), RS‑485 (DB9 A/B) |
| Baud Rates: | 4800–115200 bps; SCPI/Modbus‑RTU |
| Power: | 100 – 240 VAC, 50/60 Hz |
| Operating Temp. & Humidity: | 5 °C – 40 °C, 20 %–80 %RH (non‑cond.) |
| Storage Temp: | –10 °C – 50 °C, ≤ 80 %RH |
| Altitude: | ≤ 2000 m |
| Size & Weight: | 214 × 88 × 340 mm; ~3.3 kg |
Applications:
- Production Lines.
- Testing & Quality Inspection.
- Laboratory & R&D.
- Scientific Research.
- Field Service & Maintenance.
Package Contents:
- 1x Main unit (UTE9802+ digital power meter)
- 1x Power cable
- 1x RS‑232 communication line
- 1x User’s manual & software download guide



Reviews
There are no reviews yet.