Safety Instructions:
- Make sure battery has the enough voltage for the controller to recognize battery type before first installation.
- The battery cable should be as short as possible to reduce loss.
- Regulator is only suitable for lead-acid batteries: open, AGM, gel is not suitable for nickel metal hydride, lithium ions or other batteries.
- The charging regulator is only suitable for regulating solar power units. Never connect another charging source to the charging regulator.
Product Fratures
- Build in a small industrial console.
- One-key setting, digital screen.
- Fully 4-stage Boom charge management.
- Built in short-circuit protection, open protection circuit, reverse protection, during load protection.
- Reverse current protection, low heat production.
Specification
- Rated charge current: 10A
- Rated load current: 10A
- Work voltage: 12/24 V Auto
- Over load,short circuit protection: 1.25 rated load current 60 sec., 1.5 rated load current 5 sec. , over load protection action. ≥3 Rated load current short circuit protection action
- No load current: ≤6mA
- Charging circuit voltage drop: ≤0.26V
- Load circuit voltage drop: ≤0.15V
- Over voltage Protection: 14.8V
- Work temperature: industry stage -35C to +35C
- Boost charge voltage: 14.6V (keep 10min.)
- Direct charge voltage: 14.4V (keep 10min.)
- Float charge voltage: 13.6V
- Charge return voltage: 13.2V
- Lower voltage indicate: 12V
- Over discharge voltage: 11.1v (no load)
- Over discharge return voltage: 12.6V
- Controle mode: PWM charge mode;modified discharge voltage by the discharge rate
Communication system
- Connect the battery to charge regulator – plus and minus. <1> will appear if 12 V detects a battery, <2> if 24 V detects a battery.
- Connect the solar heater unit to the regulator-plus and minus.
The system reverse applies when uninstalling!
Improper sequence arrangement can harm the controller!
Setup / setting system
Press the setup button to activate the display mode, press the button for 3 seconds, and select the desired mode.
Show status description
0 charge only only use charge function from controller. The resulting load is forever closed
1-13 Light-open + delay load on after sunset and closed after 1-13hours
L D2D dusk to dawn (delay)
C system always load output (unless battery is low)
H hand open download manually
D patch dusk to dawn (no delay)
Note: When the screen flashes on <vu>, the description has been in temperature, over current, or lost. Outside of short circuit protection, this time should reduce the load or eliminate the short circuit, after entering the protection, and solution in addition to the exceptiopn system will delay a period of time to open the output.