Temperature Controller – 220V 1500W

This delicate digital display temperature controller can set start and stop temperature. The display and control temperature can be set to 0.1℃ with wide temperature control range from -50℃ to 110℃. It is convenient to install and wiring is simple. Widely used in the hatching area, equipment case, air conditioning system, temperature control protection and other fields.

Quick Specifications:
  • Model: XH-W3002
  • Temperature measuring range: -50 ~ 110℃
  • Temperature control range: -50 ~ 110℃
  • Temperature measurement accuracy: ±0.2℃
  • Temperature control accuracy: ±0.1℃
  • Input measurement: NTC10K probe L = 1 meter waterproof
  • Input power: 220V
  • Output Capacity: 10A
  • Dimensions: 86 x 45 x 31 mm
  • Net Weight: 52g
Dimensions

XH-W3002-220-V-005

Board Layout

XH-W3002-220-V-003

Wiring

XH-W3002-220-V-004

How To Use:
  1. Press the up button show the starting temperature.
    Long press UP button the temperature display Flashing , press the UP or Down button Set the start temperature value
  2. Press the Down button show the Stop temperature.
    Long press Down button the temperature display Flashing , press the UP or Down button Set the stop temperature value

 

   Code    Code Description    Setting Range    Factory setting
   P0    Starting Temperature    -50 ~ +110°C    25°C
   P1    Stop Temperature    -50 ~ +110°C    40°C
   P2    Temperature Correction    -10~ +10°C    0°C
   P3    Delayed Start    0-10 minutes    0

P0. Set the startup temperature:

Press the Setup button to enter the internal menu. The default display is P0. Press the Setup button again and set the desired startup temperature by pressing the up and down buttons.

P1. Set the stop temperature:

Press the setup button to enter the internal menu, the display is P0, switch to P1 by the up and down keys, press the setup button again, and set the required stop temperature by the up and down buttons.

P2. Set the temperature correction:

In the same way, enter the internal menu, switch to P2 by pressing the up and down buttons, press the setting button again, and set the required calibration temperature by pressing the up and down buttons. (Note: In the setting, if the detected temperature value is 0.5 °C larger than the actual temperature value, then the calibration temperature to be set is -0.5 ° C. If the detected value is 1 ° C smaller than the actual temperature value, the set calibration temperature is required. It is 1 ° C. Detection temperature + correction temperature = actual temperature.)

P3. Set the delay start:

In the same way, enter the internal menu, switch to P3 by pressing the up and down buttons, press the setting button again, and set the required delay time by the up and down buttons, the unit is minute. (Note: Delay start is generally used for compressor refrigeration. If it is used in refrigerator freezer, this value needs to be set. According to compressor back pressure, the general setting is 3-6 minutes, if you are not using it for control or doesn’t need delay function, skip directly.