Technical Parameters
- Overcharge detection voltage: 4.25±0.05V
- Overcharge release voltage: 4.23±0.05V
- Over-discharge detection voltage: 2.45 ± 0.1V
- Upper limit continuous current: 2A
- Overcurrent detection current: 2.5A
- Charging voltage: 4.2V
- IC component: DW01+8205A
- Quiescent current: < 30uA
- Product size: 14mm x 2mm
The Main Function
Overcharge protection, over-discharge protection, short circuit protection, over-current protection
Wiring Instructions
B+: Connect the battery positive
B-: Connect the battery negative
P+: input positive for battery pack output
P-: Input negative for battery pack output