Home
Shop
Shipping across Egypt
WhatsApp support+20 121 198 1188Hotline+20 248 813 824
عربي

FNIRSI® LC1020E High Precision Handheld Digital Bridge LCR ESR Tester

FNIRSI® LC1020E High-precision handheld LCR and ESR tester commonly used for measuring capacitors, inductors, resistors, impedance, and ESR in electronics repair and laboratory testing.

5,200.00 EGP

In stockSKU 3496300150465
Buy Now
Shipping across EgyptDelivered to your door
Cash on deliveryPay when your order arrives
Not sure it fits your project?Ask us on WhatsApp - we reply fast
FNIRSI® LC1020E High Precision Handheld Digital Bridge LCR ESR Tester

FNIRSI® LC1020E High-Precision Handheld LCR Meter is a portable and intelligent tool for testing electronic components, ideal for engineers, technicians, and hobbyists. It supports L/Q, C/D, and R/D measurements with series/parallel models, and features a 2.8-inch TFT color display.
With preset thresholds and audio-visual alerts, it enables fast pass/fail judgments, improving batch testing and quality control. Supporting up to 100 kHz test frequency, it handles high-frequency analysis of inductors, capacitors, and resistors. Its compact, battery-powered design allows precise, cable-free measurements anytime, anywhere.

Features:
  • High-Precision Measurement with 4.5-Digit Resolution
    Achieves up to ±0.05% basic accuracy, offering 10× improved precision for professional-grade measurements.
  • Wide Parameter Support
    Measures L/C/R/Z values with automatic mode switching, and displays X/D/Q/θ/ESR as secondary parameters for comprehensive component analysis.
  • Smart Auto Component Identification
    Automatically recognizes R/L/C components and switches modes instantly — ensuring fast and efficient testing with minimal manual input.
  • Multi-Frequency & Test Voltage Selection
    Supports 5 test frequencies: 100Hz, 120Hz, 1kHz, 10kHz, 100kHz
    Offers 3 RMS test levels: 0.1V, 0.3V, 0.6V — providing precise control across different testing scenarios.
  • Sorting & Comparison Function
    Set nominal values and tolerances (0.1%–99.9%) for automatic pass/fail judgment, with audio-visual prompts for fast batch testing and quality control.
  • Internal Bias Voltage
    Built-in bias voltage stabilizes readings and enhances measurement accuracy for sensitive components.
  • Dual Test Ports: 3-Terminal & 5-Terminal (4-Wire Kelvin)
    Ensures both ease of use and maximum accuracy by minimizing lead resistance error.
  • Dual-Parameter Display on 2.8″ TFT Screen
    Clearly shows both main and secondary parameters in real time — easy to read anytime, anywhere.
  • Open & Short Calibration
    Calibrate test fixtures and eliminate system errors for accurate and repeatable results.
  • Data Hold & Logging Mode
    Short press to hold reading, long press to enter logging mode — with categorized statistics on pass/fail results for improved test efficiency.
  • Compact & Rechargeable Design
    Lightweight, portable body powered by a 3.7V 3000mAh lithium battery, perfect for lab, production line, and field use.

Specifications:
Parameter Specification
Model: LC1020E
Test Frequency: 100 Hz, 120 Hz, 1 kHz, 10 kHz, 100 kHz
Basic Accuracy: 0.3%
Display: 2.8‑inch TFT LCD display
Display Digits: Main Parameter: 4.5 digits
Secondary Parameter: 4.5 digits
Measurement Parameters: Main Parameters: AUTO / R / C / L / Z
Secondary Parameters: X / D / Q / θ / ESR
Measurement Range: L: 0–100 H
C: 0–100 mF
R: 0–10 MΩ
Internal Bias: 0.0 V, 0.5 V
Test Level: 0.1 V, 0.3 V, 0.6 V
Calibration Functions: Open circuit calibration, Short circuit calibration
Comparison Function: Used to calculate the relative error between the component measurement value and the nominal value, displayed as a percentage, and provides filtering results. Nominal values and tolerance can be set, with tolerance range adjustable from 0.1% to 99.9%
Function Record: Checks if the measured component data meets the set nominal value and tolerance, recording the number of successful and failed measurements
Test Terminal Configuration: Three‑terminal, Five‑terminal
Output Impedance: 100 Ω
Communication Interface: USB‑TypeC (Virtual serial port)
Others: Language settings, Screen brightness, Sound settings, Auto power‑off, Calibration settings, System information

Resistance (R)

Range 100 Hz 1 kHz 10 kHz 100 kHz
1 MΩ – 10 MΩ 5% ± 4 digits 3% ± 3 digits / /
1 kΩ – 1 MΩ 0.4% ± 4 digits 0.2% ± 2 digits 0.3% ± 3 digits 0.6% ± 5 digits
1 Ω – 1 kΩ 1.5% ± 4 digits 0.3% ± 2 digits 0.3% ± 3 digits 0.6% ± 5 digits
10 mΩ – 1 Ω 4% ± 4 digits 2% ± 5 digits 2% ± 5 digits 5% ± 5 digits

Inductance (L)

Range 100 Hz 1 kHz 10 kHz 100 kHz
1 H – 100 H 2% ± 5 digits 2% ± 5 digits / /
1 mH – 1 H 0.4% ± 5 digits 0.3% ± 2 digits 0.4% ± 3 digits 2.5% ± 5 digits
10 µH – 1 mH 3% ± 5 digits 0.5% ± 4 digits 0.5% ± 3 digits 1.5% ± 5 digits
1 µH – 10 µH / 2% ± 5 digits 2% ± 5 digits 4% ± 5 digits

Capacitance (C)

Range 100 Hz 1 kHz 10 kHz 100 kHz
1 mF – 100 mF 5% ± 5 digits 3% ± 5 digits / /
1 µF – 1 mF 1% ± 4 digits 0.5% ± 5 digits 2% ± 5 digits 3% ± 4 digits
1 nF – 1 µF / 0.3% ± 2 digits 0.4% ± 2 digits 1% ± 4 digits
1 pF – 1 nF / 2% ± 2 digits 1.5% ± 2 digits 2% ± 4 digits
Applications:
  • Capacitor ESR testing.
  • Inductor measurement.
  • Resistance measurement.
  • Electronic component sorting.
  • PCB repair and troubleshooting.
  • Power supply maintenance.
  • Quality control inspection.
  • Laboratory electronic analysis.
  • DIY electronics projects.
  • Audio crossover component testing.
  • Educational electronics experiments.
  • Passive component matching.
  • Industrial maintenance and diagnostics.

Package Include:
  • LC1020E LCR Meter.
  • Data Cable.
  • Shorting Plate.
  • Kelvin Test Clip.
  • Test Leads (Black + Red).
  • User Manual.

Documents:

 

 

Back to Top
Product has been added to your cart